  Three-Pole   Load Break Switches:
 

ABS Load Break Switches and Isolators for voltages ranging from 3.3kv to 36 kv offers a high technical standard and economy over the years for the switchgear manufacture with dependability, reliabilty and versatility.

   
  Main Features:
     
  • High Operating reliability
• Simple maintenance and inspection
• High dynamic & thermal strength
• Tested in CPRI as per IS-9920 (= IEC 265)
• Special tubular arc-chutes
• Current interruption without visible arcs.
• Simple driving
• mechanism
   
  Triple Pole Load Break Switch:
xxx  

he salient feature of ABS Load Break Switch is its ability to permit load connections even under a short circuit condition without danger to the operating personnel. It complies with IEC, VDE, & IS standards. A high speed(snap action) make and break ensures a fast switching action and the very special design of arc chutes having excellent extinguishing properties for both high and low currents, suitability of mounting in horizontal or vertical plane etc. prove the versatility of these switches.

   
  Off-Load Isolator:
 
     

Due to the compact design of individual cubicles, and the feasibility of mounting the switches in different directions, economy in space is achieved , with ample scope for future extension. The triple pole load break switch can be used for switching of transformer feeders, overhead lines, capacitor banks, cable feeders, and ring mains. For protection against circuits H.T.Fuses can be offered with the switch.

 
   
 
TECHNICAL DATA: TKL 3 12/630 TKL 3 12/1250 TKL 3 24/630
Rated Voltage 12 kv 12 kv 24kv
Rated Frequency 50Hz 50Hz 50Hz
Rated Current 630 A 1250A 630A
Rated Peak Current 80KA 62.5KA 36KA
Rated Short time current/sec. 31.5KA 26.2KA(3 sec) 26KA
Rated Making Current 80KA 62.5KA 36KA
Rated Breaking Current 630A 630A 630A
Impulse Voltage,Wave shape 1.2/50MS:
i.To Earth 75KV 75KV 125KV
ii.Between Poles 75KV 75KV 125Kv
iii.Between Open Contacts 85Kv 85kv 145kv
Power Frequency Test Volatage:
i.To Earth 35kv 35kv 55kv
ii.Between Poles 35kv 35kv 55Kv
iii.Between Poles 45kv 45kv 75kv
Breaking of Capacitance Load 50A 50A 50A
Closed Loop breaking Cos=0.31ND 630A 630A 630A
Rated Transformer off load breaking capacity 120A 120A 120A
Rated Line Charging breaking capacity 90A 90A 90A
 
Dimensions:
i.Between Poles(Centres)mm 150-210 150-210 175-250
ii.Between open Contacts 140 140 235
iii.Between live parts and earth mm
Making Time 35 sec.
Arc Duration 5-20 M.sec
130 130 210
   
 
Description: Type Reference
TKL 3 load switches in 11 kv 400/630 A can be offered with pole distances of 150mm or 210mm in the following configuration.
1.Basic on/off switch(Quick make, Quick Break)
2.Switch with mechanical tripping and shunt trip assembly
3.Switch with fuse base
4.Switch with fuse base and mechanical tripping feature


D
D-SA-AA
D-Uh
D-UH-SA
   
 
Note: Any accessory ,if required should be specified in addition to the above type reference.